3
Technical data
Electrical data
•
Supply voltage
•
Power consumption
•
Model
Dimensions
•
Weight
•
Length
•
Diameter max.
•
Diameter min.
•
Cable length
Typical application parameters (exemplary for module „Standard")
•
Plasma temperature
•
Treatment distance
•
Width of treatment
•
Treatment speed
Operating conditions
•
Air humidity
•
Temperature
Storage conditions
•
Air humidity
•
Temperature
4
Transport / storage
•
Store the device in a dry place. This will prevent corrosion of the electrical
contacts. It is best to use the provided case for storage and transport.
•
Protect the device from dirt and foreign objects.
•
Protect the device from falls or other hard impacts.
5
Installation
•
Remove the device from the packaging.
•
Use the external power plug to establish the power supply.
•
Ensure that the workplace is well ventilated.
Attention - Damage to device!
In order to prevent damage to the device, please ensure that you follow the advice in
chapter 7.
12
24 V DC (device) / 110 – 230 V AC (power supply)
max. 18 W
Handheld device with plug-in power supply
110 g (not including plug-in power supply)
215 mm
38 mm
27 mm
1500 mm
< 50 °C
2 – 10 mm
5 - 29 mm depending on process parameters (see chapter 6)
0 – 20 mm/s
< 80 % rel. (non-condensing)
10 – 40 °C; 50 – 104 °F
< 80% rel. (non-condensing)
0 – 60 °C; 32 – 140 °F
BA-PZ3_ML / F0354401