26
HOW TO SET E.S.P?
Installer Setting - E.S.P.
This is the function that decides the strength of the wind for each wind level and because this
function is to make the installation easier.
• If you set ESP incorrectly, the air conditioner may malfunction.
• This setting must be carried out by a certificated-technician.
FAN
SPEED
TEMP
• Precaution shall be taken not to alter the E.S.P value corresponded to each air flow section.
• E.S.P value can be varied according to the products.
• In the case of going to the next air flow rate stage by pressing the fan-speed button during
the setup of the E.S.P value, the E.S.P value of previous air flow rate will be maintained by
remembering the E.S.P value prior to the shift.
1
2
3
OPER
MODE
4
5
When pressing the
button simultaneously for more than 3
seconds, the system will be entered into
the installer setting mode.
- After entering into the installer setting
mode, select the E.S.P code value by
pressing the
button.
OPER
MODE
* E.S.P code value : 03
Select the desired air flow rate with
FAN
the
button. Whenever pressing
SPEED
the
button, [SLo→Lo→Med→Hi→Po] will
FAN
SPEED
be indicated.
Select the desired air flow rate value with
the temperature up(▲), down(▼) button.
* E.S.P value range : 0~255
- E.S.P value will be indicated at the upper
right section of the display window.
When pressing the
established E.S.P value will be set up.
When pressing the
simultaneously for more than 3 seconds after the
setting has been completed, the setting mode
will be released.
- If there isn't any button input for more
than 25 seconds, the installer setting
mode will also be released.
OPER
button and
MODE
button, currently
button and
OPER
button
MODE