Displays
Pos.
Colour
Condition
0
Green
Off
On
1
Green
The NMT state machine triggers the two−colored LED (red / green): status messages appear in
green colour, error messages appear in red colour
Off
Red
2
Red
On
3
Green
On
4
Yellow
On
I
Tip!
Current documentation and software updates concerning Lenze products can
be found on the Internet in the "Services & Downloads" area under
http://www.Lenze.com
EDK2191DB DE/EN/FR/ES/IT 1.0
Description
Communication module is supplied with voltage, but has no connection to the
basic device (basic device is either switched off, in the initialisation phase, or not
available).
Communication module is supplied with voltage and has a connection to the
basic device.
NMT_GS_OFF, NMT_GS_INITIALISATION,
NMT_CS_NOT_ACTIVE / NMT_MS_NOT_ACTIVE
NMT_CS_PREOPERATIONAL_1 / NMT_MS_PREOPERATIONAL_1
(LED flashes once within a second)
NMT_CS_PREOPERATIONAL_2 / NMT_MS_PREOPERATIONAL_2
(LED flashes twice within a second)
NMT_CS_READY_TO_OPERATE / NMT_MS_READY_TO_OPERATE
(LED flashes three times within a second)
NMT_CS_BASIC_ETHERNET
(LED is blinking at a frequency of 10 Hz)
NMT_CS_STOPPED
(LED is blinking at a frequency of 2.5 Hz)
NMT_CS_OPERATIONAL / NMT_MS_OPERATIONAL
(LED is lit permanently)
ERROR
LED is lit permanently. An error is available.
The red and green drive LED indicates the operating status of the basic device
(see Operating Instructions of the basic device)
Ethernet connection is available.
Data are transmitted or received (ACTIVITY).
Ethernet connection is available (LINK).
l
19