Opening Dimensions; Electrical - Sub-Zero ICBIW-30C Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
SIT E PR E PAR AT IO N

Opening Dimensions

W INE S TO R AG E
635 mm
OPENING
DEPTH
TOP VIEW
H
W
OPENING
OPENING WIDTH
HEIGHT
SIDE VIEW
FRONT VIEW
NOTE: 89 mm finished returns will be visible and should be finished to match cabinetry.
19
mm
TYPICAL
89 mm
89 mm
FINISHED
FINISHED
FILLER
RETURN
RETURN
W
W
FRAMELESS CABINETRY
FRAMED CABINETRY
OPE NIN G D IMENS I ONS
W
457 mm Model
457 mm
2134 mm
610 mm Model
610 mm
2134 mm
762 mm Model
762 mm
2134 mm
The depth of each wine storage model is 610 mm. Allow for
panel thickness when planning the finished opening depth.
A minimum 89 mm finished return is required on all sides of
the opening. Framed cabinets will require additional finished
filler material behind the face frame for a proper installation.
Refer to the illustration.
DUA L INS TA LLATI ON
When installing two units side by side in a dual installa-
tion, the opening width is the width of the two units added
together. A dual installation kit will be required for this instal-
lation. If a dual installation kit is not specified, a minimum
51 mm filler strip is required between units.
Dual installation kits are available through an authorized
Sub-Zero dealer.

Electrical

H
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
ELE C T R I C AL R EQ U I R EMEN T S
Electrical Supply
220-240 V AC, 50/60 Hz
Service
Receptacle
grounding-type (earthed)
ELE C T R I C AL S U PP LY L O C AT I O N
457 mm Model
610 mm Model
762 mm Model
LEFT SIDE
OF OPENING
114
A
mm
108
E
mm
FLOOR
6 mm
Electrical supply location.
CAUTION
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded (earthed).
Electrical
10 amp
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
A
Do not defeat the grounding (earthing)
152 mm
nature of the plug.
241 mm
Do not use adapter or extension cord.
Failure to follow these instructions could
318 mm
cause serious injury or death.
See installation instructions
|
subzero.com
3

Publicidad

Tabla de contenido
loading

Tabla de contenido