I NSTAL L AT IO N
Anti-Tip Bracket
W OOD F L OO R APPL ICAT IO N
After properly locating the anti-tip bracket in the opening,
drill pilot holes 5 mm diameter maximum in the wall studs or
wall plate. Use the #12 screws and washers to secure the
brackets. Verify the screws penetrate through the flooring
material and into wall studs or wall plate a minimum of 19
mm. Refer to the illustration and chart below.
CONC R ET E F L O O R A PPL ICAT ION
After properly locating the anti-tip bracket in the opening,
drill pilot holes 5 mm diameter maximum in the wall studs
or wall plate. Drill 10 mm diameter holes into the concrete a
minimum of 38 mm deep. Use the #12 screws and washers
to secure the brackets to the wall, and use the
3
/
" wedge
8
anchors to secure the brackets to the floor. Verify the screws
penetrate wall studs or wall plate a minimum of 19 mm.
Refer to the illustration and chart below.
A N T I- TI P BR AC K E T PLA CE M E N T
457 mm Model
610 mm Model
762 mm Model
A
A
A
A
FINISHED
FINISHED
FLOORING
FLOORING
WALL PLATE
WALL PLATE
SUBFLOORING
SUBFLOORING
1
/
"
1
2
WOOD FLOOR
CONCRETE
min
FLOOR
Wood floor.
Concrete floor.
CONC RETE WEDGE A NCHO R INS TA LLATION
Drill a 10 mm diameter hole any depth exceeding the
1
minimum embedment. Clean the hole or drill additional
depth to accommodate drill fines.
Assemble the washer and nut flush with the end of
2
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is flush with the
surface material.
Expand the anchor by tightening the nut 3–5 turns past
3
hand-tight position or to 34 newton-meters of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other neces-
A
sary protective devices or apparel when installing or
working with anchors.
229 mm
305 mm
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
381 mm
new concrete which has not had sufficient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
(38)

Placement

CAUTION
Before moving the unit into position, secure the door/
drawers closed and protect any finished flooring.
Use an appliance dolly to move the unit near the opening.
The front leveling legs are extended below the front rollers to
improve stability during placement. Once the unit is placed
in front of the opening, completely retract the front leveling
legs to allow the unit to be rolled into position. Front and
rear leveling legs can be adjusted from the front once the
unit is positioned.
If the unit has been on its back or side, it must stand upright
for a minimum of 24 hours before connecting power.
Plug the power cord into the grounded outlet and roll the
unit into position. Verify the anti-tip bracket is properly
engaged.

Alignment

L EV E L ING
Once the unit is in position, height adjustment can be made
from the front. Using a Phillips drive, turn clockwise to raise
the unit or counterclockwise to lower. Use the lowest torque
setting when using a power drill. Do not turn the leveling
legs by hand. Refer to the illustration below.
When the unit is properly leveled, door/drawer adjustments
are less likely to be necessary.
IMPORTANT NOTE:
Level the unit to the floor, not sur-
rounding cabinetry. This could affect the operation of the
unit, such as door closing.
WARNING
To reduce the possibility of the unit tipping forward,
the front leveling legs must be in contact with the floor.
FRONT
ADJUSTMENT
REAR
ADJUSTMENT
Leveling.