Special instructions for shallow wall cavity installations:
This plaster ground valve assembly variation should only be used when the wall cavity
restricts the depth the valve may be placed in the wall. It can be used with either the
thick wall installation when the back wall prevents the plaster ground printed face
from coming flush to the finished wall or the thin wall installation where the plaster
ground / valve assembly will not fit within the wall cavity.
Note:
Installing the valve using this method will result in the handle extending into the
shower area farther and exposing more of the valve.
Snap o Plaster Ground Cap
To reconfigure the plaster ground / valve assembly for a shallow wall cavity installation:
1. Using a pair of pliers, remove the plaster ground cap by snapping it off.
2. Remove the screw(s) holding the plaster ground to the valve.
3. Remove the #2 hole covers by prying them out with a flat bladed screw driver or drilling
them out with a 3/16" drill bit.
4. Rotate the plaster ground 90° clockwise so that the arrows on either side of the word
optional point upwards and reinstall the screws removed in step 2 into the holes marked
2.
5. Install the plaster ground per the thick wall installation or thin wall installation method
described earlier.
4. Installing Your Moen Tub/Shower Trim
4.1A
4.1B
O
P
Loosen Nut (P) to allow
1. Attach Rainshower (Q) to
Showerball (O) to rotate.
Shower Arm (H).
2. Thread Showerball (O) to
Shower Arm (H).
Rotated 90° clockwise view
4.1C
H
O
Q
O
Tighten Showerball (O) with a
wrench.
E8
4.1D
4.1E
Q
S
P
T
Hand tighten Nut (P) to secure
1. Attach Washer (S) and Hose (T)
Rainshower until Nut stops.
to Rainshower (Q).
2. Attach Washer (S) and Hose (T)
to Handshower (R).
4.2
Q
3
Turn diverter knob of Rainshower (Q) to desired shower mode.
1. Rainshower
1
2
2. Combination
3. Handshower
Threaded Tub Spout Installation
4.3A
Tub Spout Installation
1
Thread seal tape
x
y
(y) + (x) + 1/4" = Pipe Length
To determine the proper pipe length, measure from the inside elbow
shoulder to the wall (y) and from the threaded adapter inside of the
tub spout to the base of the tub spout (x), then add 1/4".
Cartridge Orientation
4.4
NO
C
D
Now you are ready to attach the handle. Rotate cartridge
stem so the notch at the end of the stem is facing
YES
down towards the drain. Insert the key stop (C) and
the adjustable limit stop (D) into stop tube as shown.
4.1F
Q
R
S
R
Dock Handshower (R) to
Rainshower (Q).
.
J
If this is a shower only
installation, skip to step 4.4.
IPS (threaded) spouts are designed to screw onto a
pipe with 1/2 inch male pipe threads. To determine
the proper pipe length, measure from the inside
elbow shoulder to the wall (y) and from the thread-
ed adapter inside of the tub spout to the base
of the tub spout (x), then add 1/4". Place thread
seal tape around the pipe threading and a sealant
(plumbers putty or caulk) around the base of the
pipe to prevent leaking behind the wall. Thread the
tub spout onto the pipe until flush with the wall.
E9
3 - 3
/ 4 "
( 9 5
m m
) M
i n .

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ins10795-18