SUBSTITUTING THE NOZZLE IN THE MAIN BURNER
•
In order to operate inside the appliance, it is necessary to empty the water container.
•
Remove the front fixing screws from the panel, remove the start up cable from the piezoelectric ignition device.
•
Unscrew the nut and lower the air regulation stirrup.
•
Using a suitable spanner, unscrew the nozzle and substitute it with the right one (see the "Technical Data" table).
•
Put the air regulation stirrup into its original position.
SUBSTITUTING THE NOZZLE IN THE PILOT BURNER
The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.
Important!
After having effected the conversion to another type of gas, it is necessary to update the data plate, indicating the type
of gas for which the appliance has been converted.
•
The appliance contains the instructions necessary for use.
•
Check the appliances for gas leaks.
•
Examin the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
•
Check the lighting and flame of the main burner.
•
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is indispensable to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must be done only by specialized personnel, observing the norms in force and our indications.
It is possible to substitute parts such as the valve, the piezoelectric lighter or gas pipes very simply. To substitute the
parts, proceed as follows:
•
Valve: after removing the front panel, unscrew the screwed fittings (5-7-8-14) of the gas connections and take out
the thermostat bulb, then substitute the faulty parts, installing the new ones.
•
To substitute the thermocouple, unscrew the pilot burner fitting, likewise the valve fitting and substitute the
element.
•
The spark plug must be unscrewed and substituted.
Attention!
Before lighting the appliance, it is necessary to wash it with water and washing-up liquid, rinse thoroughly and fill with
oil up to the level marked on the back of the container.
Pilot burner ignition
Press and turn the valve knob (fig. B pos.8) round to the
Press the Lighting push button (fig. B pos.7). The flame lights automatically and can be seen through the inspection
hole in the front panel (fig. B pos.4).
The flame could go out in which case repeat the steps.
Main burner ignition and setting the temperature
Turn the valve knob (fig. B pos.8) round to the
GB
IE
CHECKING FUNCTIONING
MAINTENANCE
SPARE PARTS
INSTRUCTIONS FOR USE
MAIN BURNER IGNITION
position.
position.