Level Two Programming (Adjustable Parameters) - Nice Moon Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35

5.2 - Level two programming (adjustable parameters)

All level 2 functions are set by default as highlighted in grey in Table 7, and may
be modified at any time as explained in Table 8 .
The parameters can be set on a scale from 1 to 8 . To check the value corre-
sponding to each LED see Table 8 . IMPORTANT – In the programming proce-
Input LED Parameter
LED
(level)
L1
Pause time
L1
L2
L3
L4
L5
L6
L7
L8
L2
Step by
L1
step
L2
function
L3
L4
L5
L6
L7
L8
L3
Motor
L1
speed
L2
L3
L4
L5
L6
L7
L8
L4
Motor
L1
discharge
L2
after
L3
closing
L4
L5
L6
L7
L8
L5
Motor
L1
force
L2
L3
L4
L5
L6
L7
L8
L6
Pedestrian
L1
or partial
L2
opening
L3
L4
L5
L6
L7
L8
6 – English
TABLE 7 - Second level functions
Value
5 seconds
15 seconds
30 seconds
45 seconds
60 seconds
80 seconds
120 seconds
180 seconds
Open – stop – close – stop
Open – stop – close – open
Open – close – open – close
Apartment block:
• In the opening manoeuvre the "Step by Step" and "Open" commands
have no effect; the "Close" command causes the movement to be inverted,
i .e . the closure of the leaf .
• In the closure manoeuvre the "Step by Step" and "Open" commands cau-
se the movement to be inverted, i .e . the leaf to open; the "Close" command
has no effect .
Apartment block 2:
• In the opening manoeuvre the "Step by Step" and "Open" commands
have no effect; the "Close" command causes the movement to be inverted,
i .e . the closure of the leaf . If the transmitted command persists for
more than 2 seconds, a "Stop" is performed.
• In the closure manoeuvre the "Step by Step" and "Open" commands
cause the movement to be inverted, i .e . the leaf to open; the "Close" com-
mand has no effect . If the transmitted command persists for more
than 2 seconds, a "Stop" is performed.
Step-by-step 2 (less than 2 sec . generates partial opening) .
Hold-to-run:
the manoeuvre is performed only if the transmitted command persists; if
the command is interrupted the manoeuvre stops .
Opening in semi-automatic mode, closing in hold-to-run mode .
Very slow
Slow
Medium
Fast
Very fast
Extremely fast
Fast opening, Slow Closing
Extremely fast Opening, Medium Closing
No discharge
Level 1 - Minimum discharge (about 100 ms)
Level 2 - . . .
Level 3 - . . .
Level 4 - . . .
Level 5 - . . .
Level 6 - . . .
Level 7 - Maximum discharge (about 800 ms)
Level 1 - Minimum Force
Level 2 - . . .
Level 3 - . . .
Level 4 - . . .
Level 5 - . . .
Level 6 - . . .
Level 7 - . . .
Level 8 - Maximum Force
Pedestrian 1 (opening of leaf M2 to 1/4 of total opening)
Pedestrian 1 (opening of leaf M2 to 1/2 of total opening)
Pedestrian 3 (opening of leaf M2 to 3/4 of total opening)
Pedestrian 4 (Complete opening of leaf 2)
Partial 1 (opening of two leafs to 1/4 of "minimum" opening)
Partial 2 (opening of two leafs to 1/2 of "minimum" opening)
Partial 3 (opening of two leafs to 3/4 of "minimum" opening)
Partial 4 (opening of two leafs to "minimum" opening)
dure, the maximum time interval that can elapse between activation of one key
and the next is 10 seconds . When this time elapses, the procedure terminates
automatically, memorising the modifications made up until then .
Description
Sets the pause time, namely the time
which lapses before automatic clo-
sure . This will only take effect if clo-
sing is active .
Sets the sequence of commands as-
sociated with the "Step-by-Step",
"Open", or "Close" inputs or the radio
control .
Note – When setting L4, L5, L7 and
L8, the behaviour of the "Open" and
"Close" commands is also modified .
Sets the motor speed during normal
travel .
Sets duration of "short inversion" of
bo th motors after performing Close
ma noeuvre with the aim of reducing
the final residual thrust .
Adjusts the force of both motors
Sets type of opening associated with
"Partial open 1" command .
In levels L5, L6, L7, L8; "minimum"
opening means the smaller opening
out of M1 and M2; for example, if M1
opens to 90° and M2 opens to 110°,
the minimum opening is 90°

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mc824h

Tabla de contenido