INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to Table 1. (All calculation in inches.)
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter
Top (Standard: 36")
C = Preferred Height of Counter Top to
Hood Bottom (Recommended 27"
to 30")
D = Height of Hood
E = Height of the Hood
Installation [A – (B + C)]
F = Height of Duct Cover [E – D]
6$)(7< :$51,1*
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF
REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY
OCCUR.
Preparations before Installation
NOTE:
TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM
ENTERING THE VENT OPENING.
-
Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
-
A straight, short venting run will allow the hood to perform more efficiently.
-
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the
performance of the hood.
-
Use duct tape to seal the joints between pipe sections.
4