Charging Refrigerant - MasterCool 69789 Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The following screen will be displayed:
NOTE: cc = ml
Open the high and low-pressure taps (if the A/C system is equipped with a single quick-connect coupling for high or low pressure, open only the
relative tap) of the machine, press F1 ▶.

CHARGING REFRIGERANT

From ASSISTED PROCEDURE, scroll with the DOWN ARROW ↓, select "Ref Charge":
*The OIL phase is disabled in case of hybrid vehicles.
Set the quantity of refrigerant required for the A/C system to be charged using one of the two procedures below.
1. Manual Operation: Set the quantity for the charge. Following are examples for each set of units.
Lb, the display will have 4 digits, two digits then a decimal point and then two digits. The cursor moves from the left to the right. If the desired
charge is 1.75 lbs, then you will enter 0 1 7 5.
Oz, the display will have 3 digits. The cursor moves from the right to the left. If the desired charge is 36 oz's, then you will enter 0 3 6.
Gr, the display will have 5 digits. The cursor moves from the right to the left. If the desired charge is 980 grams, the you will enter 9 8 0.
Kg, the display will have 3 digits, two digits then a decimal and then one digit. The cursor moves from the right to the left. If the desired charge is
1.5 Kg's then you will enter 1 5.
Lb-oz, the display will have 4 digits, two digits then a colon and then two digits. The cursor moves from the left to the right. If the desired charge
is 1 lb's 7 oz's then you will enter 0 1 0 7.
22
Oil
Manual Oil
Gas Filling
→ 3 → 0 →
Oil
Manual Oil
Gas Filling
Oil Injection
Oil
Press F1 to continue
F2 to exit
Oil Injection
End of oil injection
procedure
Press F2
ASSISTED PROCEDURE
Recovery/Recycling
Vacuum
Oil*
Ref Charge
DB
NO
30 cc
xxg
NO
30 cc
xxg
30 ml
xx.xxlb

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

69789-h

Tabla de contenido