SETUP

LAST RECOVERED QUANTITY

To see how much refrigerant was recovered during the last recovery phase.
Select F5:
Select LAST RECOVERED QTY, Press F4 ↵:
This valve gets updated after each complete recovery phase.

FILLING THE MACHINE TANK

This operation must be performed whenever the available refrigerant fluid in the tank is less than 9 lbs (4.8 kg) and must be performed when the
"Empty Tank" alarm is displayed. Recommended capacity is between 10 and 15 lbs. Obtain a tank of R134a. Connect the tank adapter fitting
(69788-332) to the R134a tank. Then, connect the high pressure hose from the tank to the high pressure valve on the machine. Open both the valve
on the external tank and the high pressure valve on the machine. If the external tank is not supplied with a liquid valve, turn it upside down to obtain
a higher delivery rate.
At the MAIN MENU select F5.
REF CHARGING
ALLOW HIGH AND LOW
PRESSURE TO EQUALIZE
CLOSE ALL VALVES
F2: WHEN COMPLETE
F1
F2
F3
Last Recovered Qty
Tank Charging
Air Purge
Language
Measure Units
Set Date & Time
LAST RECOVERED QTY
01.50 LB
F2: MAIN MENU
F1
F2
F3
SETUP
F4
F5
F6
F4
F5
F6