Translation of the original instructions
Breather valve
(Oil Filler Screw)
• Ensure that the rated working pressure of each pressurized attachment be equal to or greater thant the rated wor-
king pressure developed by the hydraulic pump.
• Always check connections before using. Alteration of this products is strictly prohibited. Use only those adapters and
attachments provided and approved by the manufacturer.
• When extension tubes and/or offset attachments are used, the rated capacity is always reduced by 50% for each
tube of offset attachment connected.
• Do not attempt to operate pump unless the Breather Valve is open.
• Do not overextend the Ram (Do not over the Warning Line on the Piston of Ram).
• Do not exceed rated capacity.
SETUP
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this document including ail text
under subheadings therein before set up or use of this product.
RAM ATTACHMENTS
1. The Extensions (2a - 2e) connect in different combina-
tions to reach desired lengths.
2. The Male Connector(B) is used to connect the female
end of the Ram (B) to a Base.
3. The Flat Base (3) is typically used on the stationary
side to spread out the force of the Ram (B).
4. The 90° V Base (7) is used to offset the force of the
Ram (B) when there is not a straight line between the
stationary side and the damaged side, or to spread
out force on curved surfaces.
5. The Cap Head (9) is typically used on the pushing end
to prevent slipping.
6. The Rubber Head (10) is typically used for popping
dents out of sheet metal such as doors or body panels
and to minimize damage to the work surface.
14
HYDRAULIC CYLINDER KIT
Handle
Pump
Release Valve
Warning Line
Hose Coupler
Ram Coupler
7. The Wedge Head (6) is used to repair small dents and
areas located in angles and tight spaces.
8. The Flange Base and Flange Head (4, 5) are used
together to allow spreading in areas that the Ram
cannot fit into.
Note: The Flange Base and Flange Head must only be
used together to prevent an off-center load.
EN
Hose
Ram