Commissioning; Filling And Venting - salmson LRE Serie Instalacion Y Puesta En Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

No.
Designation
5.8.1.3 Pump kick speed
6.0.0.0
Error acknowl-
edgement
7.0.0.0
Access disable
Tab. 7: Menu structure
9

Commissioning

Safety
Preparation
9.1

Filling and venting

Installation and operating instructions LRE, JRE
Type
Symbol Values/explanations
±
Can be set between the pump's
minimum and maximum speeds
±
For additional information, see
chapter 11.3 "Acknowledge
fault" on page 106.
±
"Access disable" inactive
(changes possible)
(for further information, see
chapter 8.6.7 "Activating/deac-
tivating access disable" on
page 88).
"Access disable" active (no
changes possible)
(for further information, see
chapter 8.6.7 "Activating/deac-
tivating access disable" on
page 88).
DANGER! Risk of fatal injury!
Failure to install safety devices of the electronic module and the
motor can cause electrical shock or contact with rotating parts,
potentially resulting in life-threatening injuries.
• Before commissioning as well as after maintenance work, all safety
devices such as module covers and fan cover that were removed
must be reinstalled.
• Keep a safe distance during commissioning.
• Never connect the pump without the electronic module.
Before commissioning, the pump and electronic module must be at
the ambient temperature.
• Prime and vent the unit correctly.
CAUTION! Risk of property damage!
Running dry will destroy the mechanical seal.
• Make sure that the pump does not run dry.
• To avoid cavitation noises and damage, a minimum inlet pressure
must be guaranteed at the suction port of the pump. This minimum
inlet pressure depends on the operation situation and the duty point
of the pump, and must be defined accordingly.
• The main parameters for defining the minimum inlet pressure are the
NPSH of the pump at its duty point and the vapour pressure of the fluid.
English
Display conditions
Is not displayed if pump kick
is deactivated
Only displayed if an error is
present