ALARMS
In case of probe failure, the display will show the following alarm messages:
"A1": Tank 1 probe disconnected
"A2": Tank 1 probe short circuit
"A3": Tank 2 probe disconnected
"A4": Tank 2 probe short circuit
"A5": Tank 3 probe disconnected
"A6": Tank 3 probe short circuit
During operation, the temperature display shows the temperature of the product
in the tanks, cyclically showing the temperature of the product first in one tank
and then in the other, every 3 seconds.
To see which tank is referred to with the temperature reading, it is necessary to
check which decimal point is being shown.
If the decimal point viewed is on the left, the temperature reading refers to the
tank 1 (see Fig.2 Page 4).
Fig.17
If the decimal point viewed is in the centre, the temperature reading refers to the
tank 2 (see Fig.2, Page 4).
Fig.18
If the decimal point viewed is on the right, the temperature reading refers to the
tank 3 (see Fig.2, Page 4).
Fig.19
SL320005700 Ed.01 - 01-2014
2 TANKS
3 TANKS
Note: If while using machine, the temperature display should
switch off suddenly, to start it again press the
temperature display should not switch on again, switch off the
machine and contact your nearest assistance centre.
Important: While using the machine, the temperature display
must always be on so as to show the temperature of the prod-
uct in the tanks.
6.5. Adjusting granita consistency
The consistency of the granita may be adjusted (+/-) by means of the screw
shown in the figure +: thicker consistency, -: thinner consistency.
Fig.20
The adjustment may be made by hand or with the aid of a suit-
able flat-tip screwdriver.
The machine comes straight from the factory with the valve (2) set in an in-
termediate position between the maximum (E) and minimum (D) consistency
points.
If you wish to raise the consistency of the product all that is needed is to turn
the valve anticlockwise (left). We can see that the tab lowers in position towards
point E (point of maximum consistency).
If you wish to lower the consistency of the product all that is needed is to turn
the valve clockwise (right). We can see that the tab moves higher in position
towards point D (point of minimum consistency).
6.6. Dispensing granita
To dispense the beverage, pull the tap lever.
Fig.21
Check the temperature of the product in the hopper on a regular
basis, using a sample thermometer to make sure that the product
remains always under the storage temperature. For machine mod-
els equipped with temperature display, also check that the tem-
perature of the product, as measured by a sample thermometer,
corresponds to the temperature shown on the machine. If there
. key. If the
- 11 _EN-