Flexicode
Key:
Ribbon save priority
Key:
Speed 1 field
Key:
Tension
Key:
Save start signal in
normal mode
Intermittent Mode
Keys:
,
,
,
Mode
Key:
Transfer ribbon correction
Key:
Expert parameters
Key:
Printhead down time
Printhead up time
Key:
Printhead valve reaction
time
122
Ribbon Save Quality:
If the ribbon save algorithm is not able due to fast changes in material speed to keep the
demanded ribbon save (ribbon correction) then the printout can be shifted to obtain the
demanded transfer ribbon saving.
Print Position:
If the ribbon save algorithm is not able due to fast changes in material speed to keep the
demanded ribbon save (ribbon correction) then the print position can be kept by an increased
transfer ribbon use.
If 0 (default value) is set, the parameter has no influence to the ribbon save.
Indication of length that is transported forwards after measuring the transfer ribbon.
SaveStartInNormMode:
If a start signal comes during the printing process the print is not interrupted but the print for the
start signal is attached directly to the current print.
,
Selection of ribbon save mode.
Off: Ribbon save set to Off.
Standard: Maximum ribbon save performance, i.e. with this setting there is no loss of transfer
ribbon (apart from the safety distance of 1 mm, so the print fields are not printed one into the
other).
0 mm = It is always so far retreated that an optimal ribbon save is reached.
Default: 0 mm
−xx mm = The retreat can be made smaller.
+xx mm = The retreat can be made larger.
Password protected menu
Enter password, press key
indicated:
PhDownT = printhead down time in ms:
Is used from ribbon save algorithm to use for the calculation of start time of printhead downward
movement.
PHupT = printhead up time in ms:
Is used from ribbon save algorithm to calculate if a field ribbon save can be made or not.
PhVReactT = valve reaction time in ms:
The time is calculated when to start with printhead upward movement.