Flexicode
Key:
Protection printing
Network
Password
Key:
Protection HTTP
Key:
Protection Telnet
Key:
Protection remote access
NOTICE!
In order to execute a blocked function, first of all the valid password has to be entered. If the correct password is
entered then the desired function can be executed.
Interface
Keys:
,
,
,
COM1 / Baud / P / D / S
Key:
Start sign / End sign
Key:
Data memory
126
In case the printer is connected to a PC, it can be useful, that the user is not able to produce a
print manually. So the password protection prevents that prints can be produced manually.
Entering a 15-digit password. The password can consists of alphanumeric and special
characters.
The communication by HTTP can be avoided.
The settings of the Telnet service cannot be changed.
The password protection prevents the remote control of the printer.
,
,
,
,
COM1:
0 - serial interface Off
1 - serial interface On
2 - serial Interface On; no error message occurs in case of a transmission error.
Baud rate:
Indication of bits which are transferred per second.
Following values are possible: 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200.
P = Parity:
N - No parity
E - Even
O - Odd
Please observe that the settings correspond to those of the module.
D = Data bits
Setting of data bits.
Value range: 7 or 8 Bits.
S = Stop bits
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
SOH: Start of data transfer block
ETB: End of data transfer block
Standard: After starting a print order the module buffer receives data as long as it is filled.
Advanced: During a current print order data is received and processed.
Off: After starting a print order no more data is received.
English
,
,
Hex format 01
Hex formal 17