Flexicode
Key:
Customized entry
Key:
Hotstart
Key:
Autoload
Key:
Layout confirmation
Key:
Standard layout
I/O Parameters
Keys:
,
,
,
I/O Port 1-8 & I/O Port 9-16
(I/O Port 1-8 & I/O Port 9-16)
Key:
Debouncing
124
Off: No question appears at the display. In this case the stored default value is printed.
On: The question referring the customized variable appears once before the print start at the
display.
Auto: The questions referring the customized variable and the quantity query appear after every
printed layout.
Auto without quantity query: The question referring the customized variable appears after
every layout without additional query for the quantity.
On: Continue an interrupted print order after switching on the module anew.
(Only if module is equipped with option Compact Flash card)
Off: After switching off the direct print module the complete data is lost.
On: A layout which was loaded once from Compact Flash card can be loaded again
automatically after a restart of direct print module.
The last loaded layout from CF card is always again loaded after a restart of direct print module.
Off: After a restart of direct print module the last used layout must be again loaded manually
from the memory card.
A common use of the functions Autoload and Hotstart is not possible.
On: A new print order is only printed after confirmation at the device.
An already active continuing print order is printed as long as the confirmation is effected at the
device.
Off: No query appears at the display of control unit.
On: If a print order is started without previous definition of layout, the standard layout (device
type, firmware version, build version) is printed.
Off: If a print order is started without previous definition of layout, an error message appears in
the display.
,
,
,
Definition of port functions. 2 sign show the current setting for each port.
The first sign specifies the following:
I
= Port operates as Input
O
= Port operates as Output
N
= Port has no function (not defined)
These settings cannot be modified.
The second sign specifies the following:
+
= Active signal level is 'high' (1)
−
= Active signal level is 'low' (0)
x
= Port is deactivated
&
= Function is executed at each change of the signal level
s
= Status can be enquired/influenced by = interface. The printer-internal
=
function is deactivated.
Indication of debounce time of the dispenser input.
Value range: 0 - 100 ms.
English