Key:
Heater resistance
Key:
Printhead temperature
Key:
Ribbon
Key:
Print examples
Key:
Input
Key:
Output
Key:
I/O status
Key:
Online/Offline
To achieve a high print quality, the indicated Ohm value must be set after replacing the
printhead.
Indication of printhead temperature. The printhead temperature corresponds normally to the
room temperature. In case the maximum printhead temperature is exceeded, the current print
order is interrupted and an error message appears at the printer display.
Selection of the used transfer ribbon length (300 m, 450 m, 600 m).
Select this menu item to get a printout with all settings.
Settings:
Printout of all printer settings such as speed, label and transfer ribbon material.
Bar codes:
Printout of all available bar code types.
Fonts:
Printout of all available font types.
Indication of level for IO parameters input.
0 = Low
1 = High
Indication of level for IO parameters output.
0 = Low
1 = High
Relevant results are counted and registered in RAM memory. The protocole get lost after
switching off the device.
RInt = Real Interrupts
The start input impulses are counted directly at the Interrupt.
Dbnc = Debounced
The start input impulses that are longer than the set debounce time are counted. Only these
start impulses can lead to a print. If a start impulse is too short, no print is released. This is
recognized by the fact that RInt is counted, Dbnc not.
NPrn = Not Printed
The debounced start input impulses that have not lead to a print are counted. Causes: no active
print order, print order stopped (manually or because of an error) or the printing system ist still
active with the processing of a print order.
PrtStrtReset = The counters are reset.
PrtStrtTime = Measured length of the last start impulse in ms.
This function is activated e.g. if the transfer ribbon is to be changed. It is avoided that a print
order is processed although the module is not ready. If the function is activated then press the
key
to change between Online and Offline mode. The respective state is indicated in the
display (Standard: Off).
Online: Data can be received by interface. The keys of the foil keyboard are only active, if you
changed in the Offline mode with key
Offline: The keys of the foil keyboard are still active but received data are not processed. If the
module is again in Online mode then new print orders can be again received.
English
.
Flexicode