Descargar Imprimir esta página

Samoa PUMP MASTER 2 Guía De Servicio Técnico Y Recambio página 6

Bomba neumatica inoxidable 3:1/ss

Publicidad

Repair and cleaning pro c e d u re/ Procedimientos de reparación y limpieza/
GB
WARNING
Before starting any kind of maintenance or repair,
disconnect the compressed air supply
and open a downstream valve to relieve the oil pressure.
F
AT T E N T I O N
Avant de procéder à toute opération d'entretien
u de réparation de la pompe, fermer l'alimentation en air
et ouvrir la vanne de sortie pour libérer la pression d'huile.
GB
Unscrew the lower part of the pump, joined with the upper one by (27 and 23). Be careful not to damage O-Ring (21).
Remove pin (14) to separate the lower part of the pump.
Remove the screws (24) and pull the air motor dolly to remove it. The air motor parts will be accessible.
Replace (16 and (18) parts if required.
Clean or replace any damaged part.
E
Desenroscar la parte inferior de la bomba, unida a la superior por (27 y 23). Tener cuidado de no dañar juntas en el proceso.
Quitar el pasador (14) para separar la parte inferior de la bomba.
Aflojar los tornillos (24) y tirar de la cazoleta hacia arriba de forma que queden todas las piezas del cuerpo motor de aire al
descubierto.
Sustituir las piezas (16) y (18) si fuera necesario.
Limpiar o sustituir las piezas deterioradas.
6
833 805 R.04/10
Samoa Industrial, S.A. · Box 103 Alto Pumarín · 33211 Gijón - Asturias Spain · Tel.: +34 985 381 488 · Fax.: + 34 985 384 163
Instructions de réparation et de nettoyage
E
y accione la válvula de salida para soltar la presión del aceite.
Air motor/ Motor de aire / Moteur d'air
ATENCIÓN
Antes de empezar cualquier tipo de mantenimiento o
reparación, desconecte el aire de alimentación