Alliance Laundry Systems D009C Instalación/Operación página 41

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5
B
A
30°
1
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening must be
sized per local codes.
2
Wall
.
2
1
CONNECT TO DRYER
4
VERTICAL EXHAUST INSTALLATION
1
Roof
2
Wall
3
2" (5 cm) Minimum
4
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening must
be sized as shown or per local codes.
Figure 27
510975
C
D
E
F
G
H
HORIZONTAL EXHAUST INSTALLATION
3
H319I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
K
1
I
J
AIR
FLOW
EXHAUST AIR FLOW
MAXIMUM LENGTH OF
DUCT 30 feet (9.1 m)
3
Clearance per Local Codes
4
No Screen or Cap
5
Clean Out Cover – Inspect Monthly
Figure 26
To reduce the risk of fire and the
accumulation of combustion gases, DO
NOT exhaust dryer air into a window well,
gas vent, chimney or enclosed,
unventilated area, such as an attic, wall,
ceiling, crawl space under a building or
concealed space of a building.
Duct Station
A
B
C
D
E
F
G
H
I
J
K
Installation
2
3
4
EXHAUST
OUTLET
WARNING
Minimum Diameter of
Collector Duct
4 inches (10.2 cm)
8 inches (20.3 cm)
9 inches (22.9 cm)
10 inches (25.4 cm)
11 inches (27.9 cm)
12 inches (30.5 cm)
13 inches (32.6 cm)
14 inches (35.6 cm)
15 inches (38.1 cm)
15 inches (38.1 cm)
16 inches (40.6 cm)
H318I
W045
39

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido