3. OPERATION
3.4 OPERATING MODES
Your radiator incorporates four operating modes.
THE 'LEARNING' MODE IS ACTIVATED AT THE FACTORY.
To change the operating mode:
Simultaneously press
time you want to change the operating mode.
Light indicator 'Operating mode' will change:
1) 'Learning' mode: 'slowly flashing' light.
2) Manual mode: light is OFF.
3) Sensor mode: fixed light.
4) 'Forced' programming mode (via Smartbox
App - not included).
1) SELF-LEARNING MODE (factory pre-set activated):
During seven days and CONTINUOUSLY, week by week, your radiator will learn your
lifestyle.
The radiator has 2 working profiles:
• Economic Profile 'PE' (Default factory settings):
• Comfort profile 'PC':
Day by day, the radiator 'learns' the presence (comfort) periods and the absence periods
(economy).
After 7 days, the radiator will start working according to the programmed presence pe-
riods (comfort) and the absent periods (economy), depending on the chosen working
profile.
and
every
This profile prioritises the ENERGY SAVINGS.
• If there is detection = Comfort mode.
• If there is no detection > 30 minutes = Economy mode.
• If there is no detection > 12 hours
This profile prioritises comfort and welfare.
• If there is detection = Comfort mode.
• If there is no detection > 30 minutes = Economy mode.
• If there is no detection > 16 hours
EN
Operating
mode light
= Anti-frost mode.
= Anti-frost mode.
IRIS / ULTRAD
EN
31