Safety Instructions; Safety Clearances - Jøtul GF 100 BF2 Instrucciones Para Instalación

Ocultar thumbs Ver también para GF 100 BF2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENglish
Gas consumption:
Natural Gas G20 approx.:
Natural Gas G25 approx.:
LPG approx:
Input effect kW:
Natural gas G20/G25:
LPG:
Output nom. effect kW: 4,6 kW max - 2,5 kW min.
Efficiency:
Gas Jets (Orifices):
Main burner
Gas
Labelled
G20
200
G25
235
G30
140
G31
140
Optional equipment: See point 12.0
1
converted.
0,57 m
/hr at full capacity
3
0,66 m
/hr at full capacity
3
0,43kg/hr at full capacity
5,8 kW max - 3,2 kW min.
5,8 kW max - 3,2 kW min.
Min. 77.%
Pilot burner
Labelled
51
51
30
30

3.0 Safety instructions

Warning! If you detect an odour of gas:
Shut off the gas to the premises.
Open all windows and doors.
Extinguish all naked flames.
Do not light the stove or any other appliance.
Do not use electrical switches or the telephone.
Contact the fire department immediately from a neighbour's
telephone.
The stove must only be installed and repaired by qualified
personnel.
Always turn off the gas supply before service.
The stove must be inspected following installation and at
least once a year by qualified personnel.
The stove must only use gas of the correct type and
pressure See technical data for more details.
The stove is pre-set for natural gas G20. If propane or
butane is to be used, the stove must to be converted with
a conversion kit.
This is only to be installed by qualified personnel.
It is permitted to install the stove against a wall made of
combustible material with the clearances specified in fig. 1.
The stove must only be used if it is connected to a vent
system approved by Jøtul.
The stove must only be installed indoors.
The minimum clearance to combustible material in front of
the stove is 700 mm.
Never store combustible gas or liquid in the same room
with the stove.
The air regulator on the burner must only be adjusted by
qualified personnel.
If any parts of the stove have been submerged in water,
contact qualified service personnel to replace these parts.
Never light the stove without the front glass in place or if
the glass is cracked.
Do not burn solid fuel in the stove.
Do not place combustible material on or near the stove, as
it becomes very hot in use.
Be aware that the stove becomes hot and make sure to
keep children and animals at a safe distance.
A suitable fireguard must be used for young children the
elderly or infirm.

3.1 Safety clearances

Min. distance from insert's heat shield to wall of flammable
material: See fig. 1.
Min. distance between furniture and the front of the fireplace:
Minimum clearances from combustible material to vent
system
Horizontal vent pipe:
From the top of the vent pipe to combustible material: 50mm
From the side and the bottom of the vent pipe to combustible
material:
Vertical vent pipe:
From all sides of the vent pipe to combustible material: 25mm
700 mm.
25mm

Publicidad

Tabla de contenido
loading

Tabla de contenido