Gas consumption:
Natural Gas G20 approx.:
Natural Gas G25 approx.:
LPG approx:
Input effect kW:
Natural gas G20/G25:
LPG:
Output nom. effect kW: 4,6 kW max - 2,5 kW min.
Efficiency:
Gas Jets (Orifices):
Main burner
Gas
Labelled
G20
200
G25
235
G30
140
G31
140
Optional equipment: See point 12.0
1
converted.
0,57 m
/hr at full capacity
3
0,66 m
/hr at full capacity
3
0,43kg/hr at full capacity
5,8 kW max - 3,2 kW min.
5,8 kW max - 3,2 kW min.
Min. 77.%
Pilot burner
Labelled
51
51
30
30
3.0 Safety instructions
Warning! If you detect an odour of gas:
•
Shut off the gas to the premises.
•
Open all windows and doors.
•
Extinguish all naked flames.
•
Do not light the stove or any other appliance.
•
Do not use electrical switches or the telephone.
•
Contact the fire department immediately from a neighbour's
telephone.
The stove must only be installed and repaired by qualified
personnel.
•
Always turn off the gas supply before service.
•
The stove must be inspected following installation and at
least once a year by qualified personnel.
•
The stove must only use gas of the correct type and
pressure See technical data for more details.
•
The stove is pre-set for natural gas G20. If propane or
butane is to be used, the stove must to be converted with
a conversion kit.
This is only to be installed by qualified personnel.
•
It is permitted to install the stove against a wall made of
combustible material with the clearances specified in fig. 1.
•
The stove must only be used if it is connected to a vent
system approved by Jøtul.
The stove must only be installed indoors.
•
The minimum clearance to combustible material in front of
the stove is 700 mm.
•
Never store combustible gas or liquid in the same room
with the stove.
•
The air regulator on the burner must only be adjusted by
qualified personnel.
•
If any parts of the stove have been submerged in water,
contact qualified service personnel to replace these parts.
•
Never light the stove without the front glass in place or if
the glass is cracked.
•
Do not burn solid fuel in the stove.
•
Do not place combustible material on or near the stove, as
it becomes very hot in use.
•
Be aware that the stove becomes hot and make sure to
keep children and animals at a safe distance.
•
A suitable fireguard must be used for young children the
elderly or infirm.
3.1 Safety clearances
Min. distance from insert's heat shield to wall of flammable
material: See fig. 1.
Min. distance between furniture and the front of the fireplace:
Minimum clearances from combustible material to vent
system
Horizontal vent pipe:
From the top of the vent pipe to combustible material: 50mm
From the side and the bottom of the vent pipe to combustible
material:
Vertical vent pipe:
From all sides of the vent pipe to combustible material: 25mm
700 mm.
25mm