Protection of persons and devices
Enclosure
Insulation resistance
Insulation of control
circuits
Short−circuit strength
Discharge current
Cyclic mains switching
Mounting conditions
Mounting place
Mounting position
Clearance
above/beneath
at the side
Supply conditions for the regenerative power supply module
AC mains operation
DC−bus operation
EDK94ARN24 DE/EN/FR/ES/IT 3.0
General data and operating conditions
EN 60529
IP 20
NEMA 250
Protection against contact in
accordance with type 1
EN 61800−5−1
Overvoltage category III
from 2000 m amsl: external measures for complying with
the overvoltage category II are required, e.g.
l
connecting isolating transformer upstream
l
connecting overvoltage protection system upstream
EN 61800−5−1
up to 2000 m amsl:
Safe mains isolation by double/reinforced insulation for
mains with neutral earthing with a rated voltage for the
external conductor/star point up to 300 V.
from 2000 m amsl:
If an overvoltage protection system is connected upstream,
additional external separating measures are required for
maintaining the safe mains isolation.
EN 61800−5−1
DC−bus connection: Not short−circuit−proof
Brake resistor connection: without restrictions
Control connections: without restrictions
EN 61800−5−1
> 3.5 mA
Cyclic mains switching of 5 times in 5 minutes is permissible
without restrictions.
in the control cabinet
vertical
Comply with the device−relating mounting instructions.
Can be installed in a row without any clearance
Connection at the assigned mains filter
Direct connection of the axis modules via terminals or
busbar systems
See the chapter on DC−bus operation in the Hardware
Manual for further information.
l
Technical data
Not in the wire range of
the lower terminals
Observe regulations and
safety instructions!
4
53