15. Transportation and storage
1. Switch off device. See Switch the device
on and off.
2. Let the device cool down completely.
WARNING
Fire danger through hot parts. Let the
device cool down completely.
3. Demount reflector and all power and
connecting cables.
4. Clean the device if necessary. See
Cleaning. Mount the protection cap.
5. Put the device and all demounted ele-
ments into the original styrofoam box and
carry and store them according to the
equirements in the technical specifica-
tions. See Technical specifications.
16. Solve problems
Problem
Flash device is switched on, but has no
function
Possible reason
• Power cord is not plugged or plugged
incorrect
• Micro-fuse is defect
Remedy
• Plug in the power cord correctly
• Change micro-fuse, see Change
micro-fuse
42
Problem
Flash shows functions, but flash triggering
not possible
Possible reason
Flash capacitor is defect
Remedy
Contact our service department
Problem
Modelling light flickers
Possible reason
Modelling light defective
Remedy
Replace the modelling light, see "Insert,
remove the modelling light"
Problem
Radio triggering facility not available
Remedy
Adjust the studio flash using the radio
remote control.
Change the remote control battery.
The following notice is shown in the display
E1
Problem with operation temperature
->
Switch off the device immediately.
Contact the service department.
E2
Problem with power output
->
Switch off the device for approx.
30 minutes. Danger of overloading
E3
Internal voltage inside the flash is too
high
->
Switch on/off the flash. If you still
have the defect, contact the service
department