1. Discharge device:
WARNING
Danger of electric shock.
Discharge the device before changing the
flash tube.
• Switch on device.
See Switch the device on and off.
• Trigger flash:
Press push-button TEST and switch off
main switch immediately.
NOTE
If you don´t switch off the main switch
within 0,5 seconds, the device will charge
anew.
• Unplug power cord.
Let the device cool down.
WARNING
anger of burning on reflector, modeling
lamp and flash tube. Please let the device
cool down for approx. 30 minutes.
3. Remove old flash tube:
• Demount reflector.
See Demount and mount reflector.
• Take out the modelling light:
Insert, remove the modelling light
• Hook off the retention clip with pliers.
• Hold the flash tube at the right and left
side of the socket.
CAUTION
Danger of cutting and splitting through
breaking flash tube. Just touch the flash
tube in the range of the plug-in contact and
not at the levitated flash ring.
• Agitate the flash tube carefully and pull it
out from the socket.
44
4. Attach new flash tube:
• Place the two plug-in contacts of the flash
tube loose into the socket.
• Press the flash tube with even, slight
pressure on the plug-in contacts into the
socket as far as it goes.
CAUTION
Danger of cutting and splitting through
breaking flash tube. Put the pressure only
on the range above the plug-in contacts
and not on the levitated ring flash.
NOTE
Press the two plug-in contacts carefully
and even into the socket as to avoid the
deformation of the wires.
• Hook in the retention clip with pliers.
• Screw in modeling lamp.
See Screw in and out of modeling lamp.
• Mount reflector.
See Mount and demount reflector.
17.4 Change micro-fuse
WARNING
Danger of electric shock and fire th-
rough short-circuit
A micro-fuse, which is not conform with
the required specifications, doesn´t protect
against the overloading of the device.
Please just use a micro-fuse, which is
conform with the required specifications.
See Technical Specifications.