NOTE
The fuse holder keeps a spare fuse.
1. Switch off device.
See Switch the device on and off.
2. Disconnect from power supply:
Unplug power cord.
3. Open fuse holder:
Use a small screwdriver to lift up the fuse
holder carefully and slightly.
Fuse Holder
4. Pull out the fuse holder with your hands
completely out of ft helot.
5. Take out the old micro-fuse.
6. Take the new micro-fuse out of the spare
slot and slide it in the center of the holder.
7. Slide the fuse holder carefully into the slot
as far as it goes.
17.5 Charge flash capacitor
NOTE
Charge the flash capacitor completely,
■ when you have used the device several
days mainly with reduced output
■ when you didn´t use the device for
several months
Thus, you can protect the life expectancy
of your flash capacitor and ensure a
continuous optimal power output.
1. Switch on device.
See Switch the device on and off.
NOTE
The modeling lamp can remain switched off.
2. Adjust maximal flash output:
Press the button, until the digital
display OUTPUT POWER shows the
value 6.0. The standby indicator LED
lights up
3. The device should remain switched on at
least 30 minutes.
4. Re-adjust the flash output on the desired
value.
18. Accessories and options
You find optimal accessories for your device
at our website.
19. Disposal and environmental
protection
Please dispose of your device at your local
disposal area at no charge.
45