GENERAL MAINTENANCE (continued)
Draining Tanks - Twist-Style Drain Cocks:
1. Verify that the compressor is turned Off.
2. Holding the handle, tilt the compressor toward the drain cocks so that they are positioned
at the bottom of the tank.
3. Turn the drain cocks counter-clockwise to open the valve.
4. Keep the compressor tilted until all moisture has been removed.
5. Turn the drain cocks clockwise to close.
Checking/Cleaning the Air Filter:
WARNING:
COOLING FINS, PUMP HEAD, AND SURROUNDING PARTS ARE VERY HOT. DO
NOT TOUCH.
1. Verify that the compressor is turned Off.
2. Remove the 2 screws on face of filter assembly.
3. Remove the filter element from the filter housing.
4. Clean filter pad with soap and water as necessary. If the filter becomes clogged or
damaged, replace filter assembly.
WARNING:
NEVER CLEAN AIR FILTER WITH A FLAMMABLE LIQUID OR SOLVENT.
EXPLOSIVE VAPORS MAY ACCUMULATE IN THE AIR TANKS AND CAUSE AN EXPLOSION,
RESULTING IN SERIOUS INJURY OR DEATH.
5. Insert filter element into the cap.
6. Re-assemble filter assembly to pump.
Consult gasoline engine manual for general maintenance procedures.