Descargar Imprimir esta página

Protemp PT-70-SS-A Manual De Usuario E Instrucciones De Funcionamiento página 9

Ocultar thumbs Ver también para PT-70-SS-A:

Publicidad

Idiomas disponibles

Idiomas disponibles

Long Term Storage:
1. Unscrew the fuel cap.
2. Using an approved siphon, remove the
Kerosene or diesel.
3. Using a small amount of Kerosene or diesel,
rinse and swirl the fuel inside the fuel tank
NOTE: NEVER MIX WATER WITH FUEL. It will
cause rust inside the tank.
4. Empty the tank completely.
IMPORTANT: Never store leftover Kerosene
between seasons, using old fuel can
damage heater.
Store Heater in a dry, well ventilated area.
-
Be sure that the storage area is free of dust
and corrosive vapors. Repack the heater
in the original packaging and keep user's
manual in an easily accessible place.
WARNING
Service:
DO NOT TAMPER WITH THE UNIT. HAVE AN
EXPERIENCED SERVICEMAN MAKE ANY
NECESSARY ADJUSTMENT OR REPAIRS.
We suggest following a maintenance schedule as
follows:
TIP: Follow the long term storage
instructions to flush the tank.
FUEL / FUEL TANK:
Flush tank every 200 hours of operation or as
needed. DO NOT flush with water, use fresh
Kerosene only.
SPARK PLUG:
Clean and re-gap every 600 hours of operation
or replace as needed. After removing the Spark
Plug, clean the terminals with a wire brush.
Re-gap the terminals to 0.140" (3.5mm)
(see Figure 12).
© 2017, Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
®
Maintenance: 70-SS / 125-OFR
Never service
heater while it is
plugged in or hot!
Figure 12
FAN BLADES:
The fan blades should be cleaned at least once
per heating season, depending on conditions.
Remove all accumulated dust and dirt with a
burst of condensed air (see Figure 13).
70-SS
PRESSURE ADJUSTMENTS:
Proper pressure is dependent on the fuel type the
unit will be running. When smoking or non-ignition
occurs, remove the lower panel. Locate the brass
screw on the fuel pump to the left of the fuel line.
The ideal pressure is 112 psi (7.9 kg/cm
If you are experiencing smoking or fuel
dripping from the unit, turn the screw clockwise
1/8 to 1/4 of a turn to increase the fuel pressure
until the unit is operating properly.
If you are experiencing extended flames
from the front of the unit, turn the screw 1/8 to
1/4 of a turn counterclockwise to reduce the air
pressure until the unit is operating properly.
Kerosene Radiant Heater User's Manual
8
Figure 13
70-SS / 125-OFR
).
2

Publicidad

loading

Este manual también es adecuado para:

Pt-125-ofr-a