TYROLIT Hydrostress AG
9.4 Travel drive
9.5 Noise level and vibrations
9.6 Battery
Page 22
Parameter
Drive type
Cooling
Parameter
Noise level at the ear of the user (L
Noise level at workplace (L
PA
Sound power level in accordance with ISO 3744
(L
)
wA
Vibrations DIN EN ISO 5349-2
*Value applies under the following condition: Travel drive is switched off and the saw blade is not
engaged. The measurement is performed with the motor under full load with the saw blade dia.1,200 mm.
Higher noise levels may be generated in cutting operation.
Parameter
Description
DP battery part number
Length
Width
Height
Capacity
Manufacturer's reference
Value
Hydraulic
Air cooling by means of cooling ribs
Value
)
83.4 dB(A)*
eq
)
80.9 dB(A)*
106.9 dB(A)*
< 2.5 m/s2
Value
Battery 12-Volt, Group Size 34
2700208
260 mm
173 mm
200 mm
630 Amps
P7405
Floor Saw FSE1240