MAINTENANCE

Warning
y
Repairs other than those described here should be
performed only by trained, qualified personnel. Contact
SENCO for information at:
+31 320 295 575.
y
Read section titled "Safety Warnings" before maintaining
tool.
y
Only use spare parts specified by manufacturer or
authorized representative.
y
All screws should be kept tight. Loose screws result in
unsafe operation and parts breakage.
y
Check monthly
y
With tool disconnected, make daily inspection to assure
free movement of workpiece contact and trigger. Do not
use tool if workpiece contact or trigger sticks or binds.
y
Squirt Senco pneumatic oil (5 to 10 drops) into the air
inlet twice daily (depending on frequency of tool use).
Other oils may damage O-rings and other tool parts.
y
Some Senco tools are Oil Free and DO NOT require oil,
Check label.
y
Wipe tool clean daily and inspect for wear. Use non-
flammable cleaning solutions only if necessary.
y
Do Not Soak.
y
Caution: Such solutions may damage O–rings and other
tool parts.
y
Dispose of cleaning materials properly.

TECHNICAL DATA

Tool Type
XtremePro Series
SBM SCN49XP
6-8,3 bar
SBM SCN65XP
6-8,3 bar

NAIL RANGE

Tool Type
Min-Max diameter mm
XtremePro Series
SBM SCN49XP
2.1-2.9
SBM SCN65XP
2.5-3.3
111
3/8 in NPT
3
270
3/8 in NPT
8
Min-max length mm 
Smooth
Ring
32-65
32-60
50-90
50-70
9

TROUBLE SHOOTING

SYMPTOM
Air leak near top of tool. / Sluggish operation
1
SOLUTION
Verify air supply / tighten screws or install Repair
Kit – See Parts Manual
SYMPTOM
Air leak near bottom of tool / Poor return.
2
SOLUTION
Clean tool / tighten screws or install Repair Kit
See Parts Manual
SYMPTOM
Other problems.
3
SOLUTION
Contact SENCO.
SYMPTOM
No illumination on Display.
4
SOLUTION
Check Battery Level, charge if required.
10.2
375
337 - 1173
11.4
275
337 - 1173
Screw
Collation Type
50-65
Wire & Plastic
50-83
Wire
Should Staple Jam Occur:
Disconnect Air Supply
Remove Fasteners
Clear the Jam
Follow loading Procedure
337-1283
314
337-1283
327
Collation Angle
16°
16°
EN