ALARM COUNTER MEMORY
1 1
Press the CNT. MEMO
• Press the CNT. MEMO button twice, then
the front display indicates "A. MEMO".
CNT MEMO
ALARM CLEAR
1
example) When the alarm recording is made
at No. 12.
Press the COUNTER button
• A-12 is indicated at the counter position
on the front display.
• From "
", the "12" indicates the
frequencies of alarm recording.
• It is possible to display up to "
• When the alarm recording is made, the
on " " the front display flashes.
COUNT
REFERENCE
The alarm sounds five times in the following cases;
• When a tape without an erasure prevention tab is inserted.
– When the series signal is entered. (long sound)
– When the alarm signal is entered.
– When the record button is pressed.
– When pressing TIMER button.
• When pressing the REC button with the tape ejected.
• When the alarm signal is entered during alarm recording.
2 2
A.MEMO
2
"
The alarm sounds continuously in the following cases;
• When the tape arrives at its end in the recording mode.
• When the alarm signal is entered for alarm recording.
– When the alarm recording is ended the alarm is released.
– The alarm is released when pressing any button.
– When the alarm signal is entered with the tape ejected.
(long sound)
Auto repeat recording
• When the rewinding is completed after the tape arrives at
its end, recording is restarted.
(The alarm sounds during rewinding only.)
• If alarm recording is made, tape is ejected.
Turn the SHUTTLE ring
clockwise or counterclockwise
• When turning the shuttle ring the tape
moves forward (backward). When it
arrives at the alarm recording in only
L6H mode encounted first, it pauses for
5 seconds and then stops.
Press the CLEAR button
• The counter position on the front display
indicates "
".
• The " " is turned off.
• When pressing the CLEAR button while
the alarm check screen is displayed, all
the data and time in memory are
erased.
CLEAR
34