WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 18).
WARNING
!
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as "Acceptable for Fan Support of 22.7
kg. (50 lbs.) or less".
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
4.1
Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet box
(Figure 19).
WARNING
!
Hanger bracket must seat firmly against outlet box. If the
outlet box is recessed, remove wall board until bracket
contacts box. If bracket and/or outlet box are not securely
attached, the fan could wobble or fall.
4.2
Carefully lift the fan and seat the hanger ball/
downrod assembly into the hanger bracket that was just
attached to the outlet box (Figure 20).
Be sure the groove in the ball is lined up with anti-rotation
tab on the hanger bracket (Figure 20).
WARNING
!
Failure to seat anti-rotation tab in groove could cause
damage to electrical wires and possible shock or fire
hazard.
WARNING
!
To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and hanger
bracket.
4. How to Hang Your Ceiling Fan
AT LEAST
7'
Figure 18
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
Figure 19
NOTE: CEILING COVER, SUPPL Y WIRES AND FAN WIRES
OMITTED FOR CLARITY.
Figure 20
12
CEILING
FLOOR
OUTLET
BOX
HANGER
OPENING
HANGER
BRACKET
ANTI-ROTATION
TAB
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD
ASSEMBLY
HANGER BALL
HANGER
BRACKET
HANGER BALL
GROOVE
ANTI-ROTATION TAB
U.L. Model No.: CF784-1