COLLEGAMENTO
(ITALIANO)
MASTER: chiusura anta ritardata;
SLAVE: chiusura anta anticipata.
Nota: regolare Ie velocita di marcia e rallentamento
diante trimmers VELL e RALL in modo che I'anta del
motore "SLAVE" chiuda in anticipo rispetto alia "MASTER".
1) Collegare i due quadri attraverso i morselli come da
figura.
2) Sui quadro elellrico relativo all'anta in chiusura anticipa-
ta selezionare:
- il dip 1 in ON per renderlo motore SLAVE
- iI dip 8 in ON
e cortocircuitare
i contalli 1-2 (se non presente di serie)
3) Nell'anta in chiusura ritardata:
- iI dip 2 in ON per renderlo motore MASTER
Eseguire solo sulla morsetliera
elellrici e Ie selezioni predisposte normalmente (es.: selet-
tore MA 7041, elellroserratura,
stabile", fotocellule 9011/9111).
4) Le funzioni "Wind Stop" e "Push & Go" vanno invece
selezionate
sui due quadri (dip 6 e 7), cosi come la
programmazione dei finecorsa (pag.20+21). Anche I'even-
tuale kit antipanico
a ballerie
entrambi i motorl.lnquest'ultimo
iI selellore funzioni, sui quadro MASTER ponticellare
morselli 1-3 (pag.14).
Le selezioni SLAVE e MASTER (punti 2 e 3) devono
essere fatte in assenza di tensione.
la tensione
dopo un reset, allendere la chiusura automa-
0
tica delle ante
se chi use, almeno 15 secondi prima di
0,
comandare I'apertura.
(ENGLISH)
MASTER: delayed door closure;
SLAVE: door closure brought forward (Ref. page 5).
N.B.: adjust the running and deceleration speeds by using
trimmers VELL and RALL so that the "SLAVE" motor's door
closes before that of the "MASTER".
1) Connect the two boards via the terminals, as shown in the
figure.
2) Set the following on the brought-forward closure door's
electric board:
-dip switch 1 to ON to turn it into the SLAVE motor
-dip switch 8 to ON
and short-circuit contacts 1-2 (if not supplied as standard)
3) On the delayed closure door:
-dip switch 2 to ON to turn it into the MASTER motor.
Make electrical connections only on the MASTER terminal
board and the normally pre-set selections (I. e.: the MA7041
selector, the electric locking device, activating the "bistable
command", the 9011/9111 photoelectric cells, etc.).
4) On the other hand, the "Wind Stop" and "Push & Go"
functions are selected ontwo boards (dip switches 6 and 7),
aswell as the programming of the end-stop (pg.20+21). The
MA7034 ballery-powered
inserted in both motors. In this last case, if the function
selector is not inserted, make jumper connections
terminals 1-3 (pg. 14) on the MASTER board.
The SLAVE and MASTER (points 2 and 3) selections
must be made with the power turned off. When power is
restored or after reselling, wait for the automatic closing of
the doors or, if already closed, wait at least 15 seconds
before activating the aperture.
ABBINATO
I MATCHING CONNECTIONS
KOMBIANSCHLUSS/CONEXI6N
MASTER i collegamenti
allivazione
comando "bi-
MA7034 va inserito su
caso se non viene inserito
Quando si ripristina
anti-panic kit, if installed, is also
I BRANCHEMENT
COMBINADA
me-
J
MORSEITJERA ..aTOM
1
MOTOR
TERMIIVAl
BlOCK
A
PLAQUE
BORNE!
MOTEUR
KlEMMBRErT
MOTOR
CUADRO DE BORNES
MOTOR
i
[101
1 __
m
", : ~ZP10
I
111111
"Slave"
[101
1 __
~~ZP10
~ 111111
with
"Master"
ACCOUPLE
. ".
-
...•
-
1
MORSETTlERA "OlORE
2
-K'TDR
1
it.
PLAQUE
BORNE!
f
KlEMMBRETT
1
CUADRO DE BORNES MOTOR
1
I
1
I
c
2
BlOCK
TERMINAL
2
MClEUR
2
MOTOR
2
10N
SON