Electrical installation
Mounting steps
How to connect the filter:
1. Connect filter input cable to terminals 1U1, 1V1, 1W1 and PE.
Connect filter output cable to terminals 1U2, 1V2, 1W2 and PE.
– Observe tightening torques!
– The PE connection must comply with EN 61800−5−1.
2. The shield must be connected with a large surface to the shield sheet (PES).
– Turn down the shield and use metal cable binders to fix it (not included in the
scope of supply, e.g. EZAMBKBM) 0.
– Alternative: Insert shield mounting kit EZAMBHXM007 (not included in the scope
of supply) and mount cable binders in addition for strain relief 1.