Control Panel; Use Of The Down, Menu And Up Keys For Programming; Quick Configuration; Loading Of Default Parameters - V2 CITY2+ Manual Del Usario

Cuadro de maniobras digital (24v) para cancelas batientes y puertas correderas
Ocultar thumbs Ver también para CITY2+:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONTROL PANEL

When power is on, the control unit checks that display correctly
operates by switching on all segments for 1.5 sec. 8.8.8.8.
Firmware version, e.g. Pr I.0, will be viewed in the following 1.5
sec. Panel will be viewed upon completion of this test.
The control panel represents the physical status of the
terminal board contacts and of the program mode keys: if the
upper vertical segment is on, the contact is closed; if the lower
vertical segment is on, the contact is open (the above picture
shows an instance where the inputs LIMIT SWITCH, PHOTOCELL 1,
PHOTOCELL 2, SAFETY RIBBONS 1, SAFETY RIBBONS 2 and STOP
have all been correctly connected).
Points being among display digits show the status of
programming push-buttons: as soon as a push-button is pressed,
its relevant point turns on.
The arrows on the left of the display show the state of the start
inputs. The arrows light when the related input is closed.
The arrows on the display right side show the gate status:
• The highest arrow turns on when the gate is into its opening
phase. If it blinks, it means that the opening has been
caused by a safety device (border or obstacle detector).
• The central arrow shows that the gate is on pause.
If it blinks, it means that the time countdown for the
automatic closing has been activated.
• The lowest arrow blinks when the gate is into its closing
phase. If it blinks, it means that the closing has been
caused by a safety device (border or obstacle detector).
USE OF THE DOWN, MENU AND
UP KEYS FOR PROGRAMMING
Programming of the functions and times of the controller is
performed using a special configuration menu that is accessed and
explored using 3 keys, DOWN, MENU, and UP, which are located
below the display.
CAUTION: Except in the configuration menu, pressing the
UP key activates a START command and pressing the DOWN
key activates a START PEDESTRIAN command.
To activate the programming modes (the display must show the
control panel), press and hold down the MENU key until -PrG
appears on the display.
Hold down the MENU key to scroll through the 4 main menus:
-PrG
CONTROLLER PROGRAMMING
-Cnt
COUNTERS
-APP
SELF-LEARNING TIME AND FORCE
-dEF
LOAD DEFAULT PARAMETERS
To enter one of the four main menus, just release the MENU key
when the menu you want appears on the display.
To move through the four main menus, press the UP and DOWN
keys to scroll through the various items. Press the MENU key to
display the current value of the selected item and change it if
needed.
key pressed
key released

QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control unit
and set it at work immediately.
We recommend following these instructions, in order to
check quickly the correct operation of control unit, motor
and accessories, and then changing the configuration in
case of any non-satisfactory parameter.
1. Call up the default configuration: see paragraph "LOADING
OF DEFAULT PARAMETERS"
CAUTION: If there is only one motor, set the open time, t.AP2,
to zero in order to inform the controller that the parameters for
motor 2 do not need to be considered.
2. Set items StoP, Fot1, Fot2, CoS1, CoS2 according to the
safety devices installed on the gate.
3. Start the self-learning cycle: see paragraph "SELF-LEARNING
OF WORKING TIMES "
4. check that the automation work properly and if necessary
modify the configuration of the desired parameters. For the
position of the item menus inside the main menu and for the
options related to each item menu, refer to the paragraph
"CONFIGURATION OF THE CONTROL UNIT".
34
Pag.37
Pag.48
Pag.35
Pag.35

Publicidad

Tabla de contenido
loading

Tabla de contenido