City2+ Function Table - V2 CITY2+ Manual Del Usario

Cuadro de maniobras digital (24v) para cancelas batientes y puertas correderas
Ocultar thumbs Ver también para CITY2+:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DISPLAY
DATA
t.AP1
0.0'' ÷ 5'.00
t.AP2
0.0" ÷ 5'.00
t.APP
0.0" ÷ 1'.00
t.Ch1
0.0" ÷ 2'.00
t.Ch2
0.0" ÷ 2'.00
t.ChP
0.0" ÷ 1'.00
t.C2P
0.5" ÷ 2'.00
no
r.AP
0.0"÷ 1'.00
r.Ch
0.0" ÷ 1'.00
t.SEr
0.5" ÷ 1'.00
no
SEr.S
Si / no
t.ASE
0.0" ÷ 1'.00
t.inv
0.5" ÷ 1'.00
no
t.PrE
0.5" ÷ 1'.00
no
Pot1
30 ÷ 100%
Pot2
30 ÷ 100%
Po.r1
0 ÷ 70%
Po.r2
0 ÷ 70%
P.bAt
Si / no
SPUn
Si / no
rAM
0 ÷ 6
SEn1
0.0A ÷ 14.0A
SEn2
0.0A ÷ 14.0A
t.rAL
0.5"÷22.5"
no
t.CVE
0.0" ÷ 3.0"
St.AP
no
ChiU
PAUS
St.Ch
Stop
APEr
St.PA
no
ChiU
SPAP
no
ChiU
PAUS
Ch.AU
no
0.5"÷ 20.0'
Ch.tr
no
0.5"÷ 20.0'
PA.tr
no / Si

CITY2+ FUNCTION TABLE

DESCRIPTION
Open time gate panel 1
Open time gate panel 2
Open time pedestrian gate
Close time gate panel 1
Close time gate panel 2
Close time pedestrian gate
Close time gate panel 2 during pedestrian cycle
- Function disabled
Open gate delay
Close gate delay
Electric lock activation time
- The lock is not excited (corresponds to a value of 0)
Silent Locking Mode
Advance lock time
Pressure surge time
- Pressure surge disabled (corresponds to a value of 0)
Advance Blinking Time
- Advance blinking disabled (corresponds to a value of 0)
Power motor 1
Power motor 2
Power motor 1 during slow-down phase
Power motor 2 during slow-down phase
Maximum motor power during battery operation
Breakaway
Starting ramp
Obstacle Sensor for Motor 1
Obstacle Sensor for Motor 2
Slow-down time (b-2)
- Slow-down disabled
Fast close time after slow-down during closure
Start on open
- The START command is not received
- The gate closes
- The gate goes into pause
Start on close
- The gate finishes the cycle
- The gate opens again
Start on pause
- The START command is not received
- The gate closes
Pedestrian start on open
- The P. START command is not received
- The gate closes
- The gate goes into pause
Automatic re-close.
- Automatic re-close is activated (corresponds to a value of 0)
- The gate recloses after the set time
Closure after passage
- Closure after passage disabled (load Ch.AU)
- The gate recloses after the set time
Pause after passage
MEMO
DEFAULT
DATA
22.5''
22.5''
6.0''
23.5''
23.5''
7.0''
2.0''
1.0''
3.0''
2.0''
Si
1.0''
no
1.0''
100
100
50
50
Si
Si
4
0.0A
0.0A
no
0.0''
PAUS
StoP
ChiU
PAUS
no
no
no

Publicidad

Tabla de contenido
loading

Tabla de contenido