Motor 2 power
This menu allows adjusting the motor 2 power.
The displayed value is the percentage of max. motor power.
Power Motor 1 during slow-down phase
This menu allows you to regulate the power of motor 1 during the
slow-down phase.
The value displayed represents the percentage of the maximum motor
power.
Power Motor 2 during slow-down phase
This menu allows you to regulate the power of motor 2 during the
slow-down phase.
The value displayed represents the percentage of the maximum motor
power.
Maximum motor power during battery operation
During battery operation, the controller is powered with a lower voltage
compared to mains power. For this reason, the power of the motors is
reduced compared to normal operation and may not be sufficient to
move the gate panels effectively.
This menu allows you to activate the motors at their maximum power
during battery operation.
Si
Maximum motor power
no
Motor power at the parameters set in the Pot1
and Pot2 menus.
Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, its doors could not
move.
In case the SPUn (pickup) function is activated, for the first 2 seconds of
motion of each door, the control unit will ignore both Pot1 and Pot2
values and it will give motors the maximum power command in order to
overcome the gate inertia.