Intended Use - Festo CPX-FVDA-P2 Traducción Del Manual De Instrucciones Original

Ocultar thumbs Ver también para CPX-FVDA-P2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
CPX-FVDA-P2

Intended use

The output module CPX-FVDA-P2 is intended as a switch-off module for securely
switching off connected consumers (safety function) if the following conditions are
met:
The connected consumers go into a safe status in the event of safety switch-
off.
The safety function is achieved through two-channel P- and M-side switch off of
the following load voltage supplies of the CPX terminal:
Load voltage supply for valves U
the module). Through this are supplied the right-side-mounted valve terminal
pneumatics modules of the CPX terminal.
Two outputs (output channel CH1 and CH2 of the module) available through
the connection technology of the module. also supplied via U
In addition,the unswitched load voltage supply U
connection technology of the module as operating voltage for the external com-
ponents (auxiliary supply DC 24 V).
The output channels of the CPX-FVDA-P2 form with their connected consumers one
safety circuit each.
The output module CPX-FVDA-P2 is a product with safety-relevant functions and is
intended for installation in machines or automation systems and for use as fol-
lows:
in excellent technical condition
in original status, without unauthorised modifications
exclusively in the configurations named in the description
P.BE-CPX-FVDA-P2-...
within the limits of the product as defined by the technical data (
in an industrial environment
Note
Observe that the safety engineering system limits of the output module are its
physical limits.
Festo CPX-FVDA-P2-Z6 1209NH English
of the CPX terminal (output channel CH0 of
VAL
is made available through the
VAL
.
VAL
chapter 7)
33

Publicidad

Tabla de contenido
loading

Tabla de contenido