5

Commissioning

Start behaviour of the output module

For the on site diagnostics, the following LEDs are located under the transparent
cover of the module:
1
Module error LED
(red)
2
FP-LED (green) -
Failsafe Protocol
3
Channel error LED
(red); one for each
output channel
4
Status LED (yellow);
one for each output
channel
Fig. 5:
Note
The LED display of the module is not designed in a safety-oriented way.
S Observe that the LEDs must not be evaluated for safety-oriented measures.
When the operating voltage supply U
1 lights up for approx. 500 ms. When the load voltage supply U
the channel error LEDs 2 light up for approx. 1 s.
Any switch on sequence is acceptable from the perspective of the output module.
If both voltage supplies are switched on simultaneously, the specified LEDs light
up in common.
Until correct parameterisation through a PROFIsafe master, the FP-LED flashes.
After correct parameterisation, the FP-LED lights up and the module is ready for
operation.