13. WASH CYCLE SELECTION

A
A:
Cycle Start - Cycle Stop - Cycle Selection 1-2-3 ∞, Self-cleaning
B:
On/Off (Stand-By) - Cycle Stop - Alarm Reset
C:
Regeneration (optional) - Cold rinse selection (when provided for)
D:
Drain (when provided for)
t= Tank temperature*
b= Boiler temperature*
* to intervals of approximately a second
The wash cycle can be selected by pressing the key
The cycle selected is signalled by lighting of the relevant LED (see front panel).
4 selections can be made:
cycle 1: the wash time of this cycle is factory-set to 120sec
cycle 2: the wash time of this cycle is factory-set to 180sec
cycle 3: the wash time of this cycle is factory-set to 240sec
cycle 4: the wash time of this cycle is factory-set to 300sec.
Note:
the other times, which cannot be changed, relevant to the cycle are given below:
pause time after wash: 3sec
if the parameter (Flowswitch) is not enabled, hot rinse time: 15sec

14. GENERAL OPERATION CYCLE

With the machine activated (green LED on), press the
cycle start.
Keep the button pressed for more than 5sec to select the required wash cycle.
After the type of cycle has been selected, the relevant LED stays on.

14.1 Standard function cycle

The cycle sequence is as follows:
lighting of selected cycle LED
activation of wash pump for the time set in programming
Note:
the wash time can be increased if the thermostop function is activated, which waits for the boiler temperature to reach
the set temperature before the cycle goes to the next phases.
at the end of wash the cycle the pump is switched off and a 3sec. pause is activated.
If the parameter
Flowswitch
at the end of the pause the hot rinse for the quantity of water delivered useful for the rinse set in programming, is activated.
If the parameter
Flowswitch
at the end of the pause the hot rinse is activated for 15sec
after 5sec from the start of hot rinse the drain pump is activated and then deactivated 10sec after the end of hot rinse,
even if the door is opened (only if the programming parameter
at the end of hot rinse the cycle fi nishes, signalled by the message End.
Note:
Another cycle cannot be restarted:
if the door is not opened
if the
Stop
button is not pressed
if the
Off
button is not pressed.
USER SECTION
cold rinse
is enabled:
is not enabled:
B
START
for more than 5sec.
Start
button for less than 1 second and release it to activate wash
Drain Pump
C
D
is enabled)