Replacing the dispenser drive chain
For this operation, proceed as outlined below.
1) Loosen the nuts (A).
2) Remove the casing (B).
3) Move the tensioner (C) and remove the chain (D).
CAUTION
The tensioner could move unexpectedly, causing in-
jury to the hands.
Proceed with the utmost caution.
4) Fit the chain on the pinions and the tensioner.
NOTICE
Fit the chain with the joining link positioned as
shown in the figure.
5) Position the casing (B).
6) Tighten the nuts (A).
Replacing the gripper
Carry out the operations described.
1)
Unscrew the nuts (A).
2)
Remove the screw (B).
3)
Remove the screw (C).
4)
Remove the bushing (D).
5)
Remove the gripper (E).
6)
Remove the lever (F).
7)
Set the new gripper into place.
8)
Position the lever (F).
9)
Position the bushing (D).
10) Insert the screw (C).
11) Insert the screw (B).
12) Tighten the nuts (A).
English language
INFORMATION CONCERNING REPLACEMENTS
C
D
UN41 0599GN
UN41 0596GN
33
A
A
8
A
B
F
E
B
D
C
Use and maintenance