No change in measurements if connected
with drain illustrated (K-7193BR).
Cut-out 1867 mm (73-1/2") x 1003 mm
39-1/2").
Pump/Control Access
1016 mm (40") W x 381 mm (15") H
800 mm (31-1/2")
51 mm (2")
25 mm (1")
1. Prepare the Site
NOTICE: The floor support under the whirlpool must provide for a minimum of 907.2 kg (2000 lbs).
Two separate 240 V electrical services are required: one for the pump/control, and one for the
heater.
Consult local and national codes for minimum air gap requirements when installing a spout on the
faucet deck.
The overflowing bath must be filled through the bathing well.
Hot water supply should be 70% of the capacity or greater.
The fixture conforms to CSA B45.5/IAPMO Z124. All dimensions are nominal.
There is no change in measurements if connected with the drain illustrated (K-7193BR).
Cutout = 1867 mm (73-1/2") x 1003 mm (39-1/2")
An access panel is required. The recommended dimensions for this access panel are 1016 mm (40")
W x 381 mm (15") H. Refer to the specification sheet for suggested access panel location.
Make sure the flooring is in good condition and offers adequate support for your bath.
IMPORTANT! Verify that the subfloor is flat and level. This will help minimize the leveling adjustments
necessary for proper product performance.
Kohler Co.
1905 mm (75")
635 mm
(25")
25 mm (1")
English-5
427 mm
(16-13/16")
610 mm (24")
73 mm (2-7/8")
76 mm (3")
1041 mm
(41")
521 mm
(20-1/2")
184 mm
(7-1/4")
140 mm
(5-1/2")
1-1/2" NPS
1-1/2" OD
1019731-BR2-A