Descargar Imprimir esta página
Emerson White-Rodgers 36H32 Serie Manual De Instrucciones

Emerson White-Rodgers 36H32 Serie Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 36H universal gas valves are designed for use on automatic
spark ignition systems. The valves are shipped from the factory
set for natural gas non-piloted applications. See the Installation
Instructions included with the valves for proper installation.
This document shows the modifications required if the valve is
to be installed on an LP gas and/or piloted gas application.
LP GAS CONVERSION
For LP gas conversion, use the LP conversion kit supplied
separately with this control. Refer to the instructions packed
separately with LP conversion kit.
PILOTED GAS APPLICATIONS
WIRING
These valves are shipped with an external wire jumper installed
for non-piloted gas applications. For applications requiring piloted
gas, such as intermittent pilot or spark-to-pilot systems, remove
the external wire jumper from the main (M) and pilot (P) valve
terminals (see figure 1).
SW1
C
SW2
EXTERNAL
(-)
JUMPER
SW1
P
SW2
PILOT (REDUNDANT)
M
TWO STAGE
MODELS ONLY
HI
Figure 1. Gas valve internal wiring and terminal
identification
Refer to the 36H Series Installation Instructions for additional
system wiring information.
(+)
(-)
RECTIFIER
RECTIFIER
MAIN
(+)
(-)
RECTIFIER
2ND
STAGE
The Emerson logo is a
trademark and a service mark
of Emerson Electric Co.
36H UNIVERSAL GAS VALVES
CONVERSION INSTRUCTIONS
Model
No.
36H32-XXX
36H33-XXX
36H64-XXX
36H65-XXX
PILOT GAS CONNECTION
These gas valves are shipped with the pilot outlet plugged. For
installations requiring pilot gas, remove the plug from the pilot
gas outlet (see figure 2) and use the fitting packed separately
with the valve.
Install the fitting into the pilot gas outlet, turning until finger tight.
Insert clean, de-burred ¼" O.D. tubing all the way through the
fitting. While holding the tubing securely, slowly tighten the fit-
ting until you feel a slight "give". Tighten the fitting an additional
1-1/2 turns.
(+)
The plug should not be removed for a Direct Burner Ignition
system such as Direct Spark or Hot Surface Ignition.
Refer to the 36H Series Installation Instructions for pilot flame
adjustment information.
Pilot Gas
Outlet
Main Gas
Outlet
Figure 2. Gas valve outlet end
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
FIELD
No.
Opening
of Stages
Characteristics
1
Fast
1
Slow
2
Fast
2
Slow
PART NO. 37-6658D
Replaces 37-6658C
Outlet
Pressure
Tap
0927

Publicidad

loading

Resumen de contenidos para Emerson White-Rodgers 36H32 Serie

  • Página 1 Refer to the 36H Series Installation Instructions for additional system wiring information. Figure 2. Gas valve outlet end White-Rodgers is a division PART NO. 37-6658D The Emerson logo is a of Emerson Electric Co. Replaces 37-6658C trademark and a service mark 0927 www.white-rodgers.com...
  • Página 2 Figura 2. Extremo de la salida de la válvula de gas White-Rodgers es una división Nº DE PIEZA 37-6658D El logotipo de Emerson es una marca de Emerson Electric Co. Reemplaza 37-6658C comercial y una marca de servicio de www.white-rodgers.com...

Este manual también es adecuado para:

White-rodgers 36h33 serieWhite-rodgers 36h64 serieWhite-rodgers 36h65 serie