Natural Gas - Remington REM-B300LT-F Manual Del Usuario Y Instrucciones De Operacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CAUTION
sediment trap should be located within reach for cleaning and where it is not likely to freeze. Install it in the
piping system between the fuel supply and heater. This keeps contaminants from getting into the heater
controls. The heater may not run properly if the sediment trap is not installed or is installed incorrectly.
CAUTION
(R-Series). Your gas supplier provides an external regulator for natural gas.
INSTALLATION ITEMS NEEDED (NOT PROVIDED):
• 8" Adjustable Wrench
• 8" Pipe Wrench
• 3/8" Flexible Gas Line (24" Min.) or 1/2" Black Pipe
• 90 Deg. 3/8 NPT x 3/8" Flare Fitting or 3/8" Street Elbow
• Sealant (Resistant to natural or propane/LP gas)
• Shutoff Valve
1. Depending on where your gas supply line is located, a variety of options are possible for routing the gas
connection lines. First, install the 3/8" fitting to the heater regulator using sealant. Direct the attachment
either left or right toward the gas supply line.
NOTICE: Most building codes do not permit concealed gas connections. Check your local building code
before using a flexible gas line for this installation.
2. Install the gas line to the 90 deg. fitting, and attach it to the shutoff valve (see Fig. 12 & 13). Depending on your
connection, it might be necessary to cut and access the hole in the side or bottom of the mantel cabinet.
3. Check all connections for gas leaks.
Fig. 12—Gas Inlet to Regulator
©2017 Pinnacle Climate Technologies
Installation (cont.)
Use pipe joint sealant that is resistant to gas (propane or NG). We recommend that you
install a sediment trap in a supply line, which traps moisture and contaminants. The
Avoid damage to the regulator. Hold the gas regulator with a wrench when connecting
into gas piping and/or fittings. NG Models:
6" to 7" W.C. (B-Series) / 5" to 11" W.C.
Fig. 13—Attaching the Flexible Gas Line
to the Equipment Shutoff Valve
To Regulator
Flexible Gas Line or
Black Pipe to Heater
Cabinet Regulator
18
Vent-Free Gas Heater User's Manual
EQUIPMENT
SHUTOFF
VALVE
PROPANE/LP
To External Regulator

NATURAL GAS

To Gas Supply

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido