Inspecting Burners - Remington REM-B300LT-F Manual Del Usuario Y Instrucciones De Operacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSPECTING BURNERS

Check the pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The
incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 21:
• Turn the heater off (see TO TURN OFF GAS TO THE HEATER, pages 21–22).
• See the TROUBLESHOOTING GUIDE,
Fig. 20—Correct Pilot Flame Pattern
WARNING
©2017 Pinnacle Climate Technologies
page
Do not allow fans to blow directly into the heater. Avoid any drafts that alter
burner flame patterns.
Operation (cont.)
25.
23
Fig. 21—Incorrect Pilot Flame Pattern
Vent-Free Gas Heater User's Manual