1. STOP! Read all the above safety information before proceeding.
2. Turn the control knob clockwise
(see Fig. 18).
3. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B" in
the safety information above. If you don't smell gas, go to the
next step.
4. Turn the control knob counterclockwise
position.
5. With control knob depressed, push down on the ignitor button
until the pilot lights. The pilot is located behind the heater
screen centered on the burner (see Fig. 19).
• Do not attempt to light the pilot by hand.
6. Keep the control knob depressed for (30) seconds after the
pilot lights. Then release the control knob.
• If the control knob does not pop up when released, stop and
immediately call a qualified service technician or gas supplier.
• If the pilot goes out, repeat steps 3 through 6. Wait (1) minute
before attempting to light pilot again. If after several tries the
pilot still goes out, turn the gas control knob clockwise
to the "OFF" position and call a qualified service technician.
7. Turn the control knob counterclockwise
setting (see Fig. 20).
1. Turn the control knob clockwise
Shutting Off the Burner Only (Pilot Stays Lit):
1. Turn the control knob clockwise
©2017 Pinnacle Climate Technologies
Manual Control Operation
LIGHTING INSTRUCTIONS
to the "OFF" position
to the "PILOT"
to the desired
TO TURN OFF GAS TO THE HEATER
to the "OFF" position.
to the "PILOT" position.
22
Fig. 18—Control Knob
Fig. 19—Pilot
Fig. 20—Desired Setting