The accumulation and the sending of data will depend on the mode chosen in the section UF-6.
• To turn to the normal weighing mode, press the key
• If the user wants to go back to the piece counting mode, using the same sample of reference, press the key
• If the user want to change the sample of reference, the user must repeat the steps described above.
6.4 LIMITS AND ALARM
The user can configure the Low and High limits of the sample placed on the platform.
The display will show if the sample is below limit Lo, above the superior limit Hi or in the zone between the two limits OK
The user can configure to make the alarm ring.
All the procedure is described in the section UF-2.
If the user wants to define the limits in the normal weighing mode and wants to use the limits in piece counting mode, he must define the new
limits for this mode, when it changes to weight mode again, the user will recover the limits he already has. The same happens otherwise.
6.5 MONO-RANGE / MULTI-RANGE / MULTI-INTERVAL
The indicator can be configured with an Mono-range, a maximum weight and a value of step. It can also be configured as multi range or multi
interval, in such cases there is a maximum weight.
From 0 to the medium weight of these maximum weight it is used the value of the chosen step ( step 1) and from the half to the maximum weight
it is used the next value in the step ( step 2).
The screen indicators R1 and R2 point out the range which the user is using at every moment.
In the multi interval mode the weight increases, in the range use it used step 1, when the user goes to range 2 the step 2 is used.
When the weight decreases and the user go back to range 1, the step 1 is used again. On the contrary, in mode multi range, when the weight
decreases and the device go back to range 1, the device continues using step 2 until it reaches 0.
In the section LF2 of the technical parameters the user can choose the range mode.
7. PARAMETERS
8. PARAMETERS CONFIGURATION
8.1
INTERNAL COUNTING (A/D)
8.2
CONFIGURATION OF THE WEIGHT LIMITS (SUPERIOR AND INFERIOR)
8.3
AUTO SWITCH OFF
8.4
CONFIGURATION OF THE ILLUMINATION OF THE DISPLAY
8.5
HOLD FUNCTION
8.6
RS-232 DATA EXIT
8.7
CONFIGURATION OF THE SPEED OF THE AD CONVERTER
8.8
ZERO WEIGHT DISPLAY CONDITION
8.9
CONFIGURATION OF THE GRAVITY
To access the configuration of parameters when the screen is in zero, the user must press at the same time the keys
Press the key
To go back to the previous mode press the key
PARAMETER
DESCRIPTION
UF-1
Internal calculation (A/D)
Limit Configuration of weight ( superior and inferior)
UF-2
UF-3
auto auto off
UF-4
Back illumination of display
Four modes of hold
UF-5
UF-6
RS-232 Output ( PC/PRINT)
UF-7
Configuration of the speed of the converter (A/D)
UF-8
Zero Weight Display Condition
Configuration of gravity
UF-9
or
to choose the desired character (UF-1 ~ UF-9), for confirm the changes done, press
to select Kg again.
.
USER'S MANUAL IB10-S
again.
and
EN
.