When using the EPS1 card with parameters Ab02 or Ab03 (see the table on page 16), make the connections
as shown in the following figure.
After 15 minutes without touching any key, the display
shows a horizontal segment in D4. This will come on
when touching any of the ESC, ENTER, UP, DOWN
pushbuttons.
D1 and D2 (gate status):
CL
(static)
CL
(flashing)
OP
(static)
OP
(flashing)
PC
(flashing)
PO
(static)
PO
(flashing)
XX
(countdown)
StOP
PA
(static)
rS
(static)
HPÿ
(static)
12
EPS1 connections with parameters Ab02 and Ab03
Gate closed
Gate closing
Gate open
Gate opening
Pedestrian gate closing
Pedestrian gate open
Pedestrian gate opening
Gate on stand-by
Operator unlocked
Pause (operation not complete)
Gate resetting (searching for close
position)
Dead-man mode
In swing gates, C4 refers to the interior photocell and C5 to the exterior
photocell (instead of opening and closing, respectively).
Door or gate type selection (C3)
6
Select door or gate type:
C301: swing
C302: sliding
C303: up-and-over
N141E
DL1: red LED, L1-COM contact
DL2: green LED, L2-COM contact

Display indications

D3 and D4 (error messages):
C4
Opening safety device activated
C5
Closing safety device activated
C9
Mechanical or resistive strip activated
E1
Encoder failure motor 1
E2
Encoder failure motor 2
F1
Motor 1 thrust limit exceeded
F2
Motor 2 thrust limit exceeded
N141C
N141G
N141D