D1 D2 Parameter
A
0
Flashing light
1
Garage light time
2
Gate speed
3
Soft stop speed
5
Reverse after closing (prevents
the operator from seizing up on
the stopper)
6
Maximum trapping torque/
thrust (level of increase relative
to nominal)
The digit D3 allows the level to
be adjusted during opening;
The digit D4 allows the level to
be adjusted during closing
7
Passage through photocell
(opening or closing) during
stand-by (in automatic mode
only)
8
Effect of ST1-ST2 pushbuttons
d u r i n g s t a n d - b y t i m e ( i n
automatic mode only)
9
Opening mode
A
L a p s e b e t w e e n l e a v e s i n
opening and closing
b
Using the EPS1 card connector
For parameters Ab02 and Ab03,
use the EPS1 card and bridge the
network input cable connectors
instead of connecting them to
t h e n e t w o r k ( s e e " E P S 1
C o n n e c t i o n s f o r A b 0 2 o r
Ab03").
N
0
Programming lock key
Be sure to remember any key
used, for future access to the
programming
1
Total operations completed
2
Partial operations completed
t
0
FTP communication
1
GSM signal strength
16
Complete programming chart (and II)
D3
D4
Preset option
0
1, 2
0..5ÿ
0...9
0
1...9
0
1...9
0
0...5
2...9
2...9
0
0...2
0
0...2
0
1...3
0...9
0...9
0
0...3
0
0,1
X
X
X
X
O
ç
X
X
Options or values
01
01: output with voltage, without pre-warning
02: output with voltage, with pre-warning
03
03 = 3 sec.;
59 = 59 sec.;
2ÿ 5 = 2 min. 50 sec.;
....; maximum 4 minutes
05
01: minimum,..., 09: maximum
05
01: minimum,..., 09: maximum
00
00: no reverse;
...;
05: maximum reverse
55
22: level 2 in opening and level 2 in closing;
34: level 3 in opening and level 4 in closing;
....;
65: level 6 in opening and level 5 in closing;
...;
99: level 9 in opening and closing
02
00: does not affect stand-by time
01: immediate close when the photocells are
released
02: restarts stand-by time
02
00: have no effect during stand-by
01: produce closing after 3 seconds
02: restart stand-by time
02
01: collective opening
02: semi-automatic alternative shutdown
03: automatic alternative shutdown (when F200
is selected, A903 becomes A902)
22
00: no lapse in opening or closing (only applies in
gates without overlap);
11: minimum lapse in opening (1 second) and
closing (1 second)
23: 2 second lapse in opening and 3 second lapse
in closing
...
99: maximum lapse in opening (9 seconds) and
closing (9 seconds)
00
00: use for standard traffic light;
01: use for brakes
02: NC contact with gate open (L1-COM), with
gate closed (L2-COM)
03: impulse Open 1 second (L1-COM) when
starting opening and Close 1 second (L2-
COM) when starting closing. Allows another
board to be activated.
0000
The preset option is 0000 (no key). If any figure is
changed, this is considered a key.
Select the required key (starting with D1) using
UP and DOWN. Press ESC to cancel or ENTER to
confirm and move to D2, and so on.
Indicates the hundreds of cycles completed (for
example, 68 indicates 6,800 cycles completed)
Indicates the hundreds of cycles completed. This
can be reset by pressing ST1, ST2 and ENTER at
the same time.
Immediate communication with the server
Indicates signal strength