1. Lift the range hood up under cabinet and
determine final location by centering
beneath cabinet. Mark on the underside of
cabinet the location of the 4 keyhole
mounting slots on the range hood. Set
range hood aside on a covered surface.
2. Use ⅛" (3 mm) drill bit and drill 4 pilot
holes as shown.
3. Install the 4 - 4.5 mm x 13 mm mounting
screws in pilot holes. Leave about ¼" (6.4
mm) space between screw heads and
cabinet to slide range hood into place.
4. Remove transition knockouts depending on your model.
Round vent system installations - Remove top rectangular and round vent
knockouts.
Rectangular vent system installations - For roof installations, remove the top
rectangular vent knockout. For wall installations, remove the rear rectangular vent
knockout
Non-ducted (recirculating) installations - Do not remove any knockouts.
A. Round vent knockout
B. Top rectangular vent knockout
C. Rear rectangular vent knockout
5. Remove metal grease filters. See the "Range Hood Care" section. For the ENM
series models, first remove the lateral panels.
NOTE: You will have 3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector
inside your range hood. Some models are recirculation (non-ducted only) and will
not have vent connector
Model EFS:
A. Screws
B
B. 3¼" x 10" (8.3x24.4cm)
rectangular vent knockout
A
6. Remove the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector attached with
screws or taped on the inside your range hood.
7. For round installation: Install 7" (17.8 cm) round vent mounting plate and damper or
3¼" x 10" (8.3 x 25.4 cm) vent connector, depending on your vent system
installation. (Purchase as an accesory).
A
B
C
D
NOTE: The 3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector can be installed
up to 1" (2.5 cm) on either side of the hood center to accommodate off center
ductwork.
A
A. Keyhole
slot
Drill pilot holes
"(6.4mm)
1
4
A
B
C
A
Models ENM
A. Lateral panels
A. 7" (17.8cm) round damper
B. Sheetmetal screws
C. 7" (17.8cm) round vent mounting plate
D. Round vent knockout
E. Rectangular vent knockout
E
A
D
B
If a vent damper is installed with a wall cap with damper, check to make sure they
do not interfere with each other. Remove the vent connector damper flap if they
interfere.
Non-ducted (recirculating) installations - No vent attachments. The
ENM230 and ENM236 series models requires the removal of the recirculation
cover plate. Remove the two screws from the recirculation cover plate and remove.
A
POWER SUPPLY CABLE INSTALLATION
1. For direct wire installations, run the home power supply cable according to the
National Electric Code or CSA standards and local codes and ordinances.
There must be enough wiring from the fused disconnect (or circuit breaker) box to
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the instructions included with
the power supply cord kit.
NOTE: Do not reconnect power until the installation is complete.
2. Remove the screw from the terminal box cover. Remove terminal box cover and set
aside.
model EFS
A
B
A. Terminal box cover
3. Remove the power supply knockout from the top or rear of the vent hood (depending
on the incoming location of your home power supply cable) and install a UL Listed or
CSA approved ½" strain relief.
Power supply
knockout
4. Using 2 or more people, lift the hood into final position. Feed enough electrical wire
through the ½" UL listed or CSA approved strain relief to make connections in the
terminal box. Tighten the strain relief screws.
5. Position the range hood so that the large end of the keyhole slots are over the
mounting screws. Then push the hood toward the wall so that the screws are in the
neck of the slots. Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.
6. Connect ventwork to hood. Seal joints with clamps to make secure and airtight.
7. Check that back draft dampers work properly.
4
B
A. Vertical connector
B. 6.5 x 9.5 mm screws
C. Vent knockouts
D. Horizontal connector
C
A. Screws
B. Recirculation cover
plate
B
models ENM
B. Screw
A
B